TOSHNIWAL ENTERPRISES CONTROLS (P).LTD.  
   
   
Home Mail Sitemap
 
 
The toshniwal enterprises controls pvt. ltd. logo denotes discipline.  The line that makes the graph signifies dynamism, fast paced and simplicity in our work approach. Where as the space between them shows an infinite and a challenging environment. The T on the graph, which stands for toshniwal enterprises controls pvt. ltd., is surrounded and compact by order, ease and perpetuity.  Thus, this makes the base for toshniwal enterprises controls pvt. ltd. on which it lies.  
 
 THE COMMITMENT IS FOREVER
 
TELECOM
 
PROCESS
     
ELECTRICAL
     
CALIBRATION
     
RENTAL
NEWS
 
   
FLUKE FLUKE >> EARTH TESTERS

  Back

                     EARTH TESTERS
                            ------------------

Fluke 1620 Series GEO Earth Ground Testers

The Fluke 1623 and 1625 are distinctive earth ground testers that can perform all four types of earth ground measurement. Specifically, the Fluke 1623 and 1625 testers are able to measure earth ground loop resistances using only clamps – called Stakeless testing. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods.

Testing Methods

• 3- and 4-Pole Fall of Potential –
  standard earth ground testing using
  two ground stakes
• 4-Pole Soil Resistivity testing – determine
  soil resistivity using four ground stakes
• Selective testing – without
  disconnecting ground rods, a technician
  can measure ground resistance using
  a combination of stakes and a clamp.
• Stakeless testing – innovative solution
  using only clamps, instead of ground
  stakes, to measure earth ground
  loop resistance.


Geo 30 Earth Ground Clamp (LEM)

The Geo 30 Earth Ground Clamp simplifies ground loop testing and enables non-intrusive leakage current measurement. The HEME Geo 30 indicates and measures True RMS current flow from a few µA up to 30 A. The HI/LO function can be used to quickly evaluate the measured value by comparing against upper and lower limits and a recording function allows storage of measured values.

The Geo 30 speeds and simplifies ground / earth testing for utility specialists and lightning protection installers.

• Ground loop resistance clamp
  measurement without any disconnection
  or additional ground rods
• Low level measurement of ground
  leakage current without disconnection
  for  system troubleshooting
• Wide ac current measurement range up to
  30 A with one instrument

Handy Geo Earth Ground Tester (LEM)

The Handy Geo Earth Ground Tester is a rugged, easy to use tester for three-pole ground resistance measurements and two-pole ac resistance measurements.

Earth Ground resistance is measured by installing Earth Ground test electrodes and testing with the Handy Geo. Earth Ground resistance measurements are used to ensure safe operation and reduce power quality problems. The Handy Geo is extremely lightweight making it ideal to test for lightning protection levels and periodic check-ups during routine maintenance.

Three-pole earth resistance measurements
Two-pole ac resistance measurements
AC/DC voltage measurement
Large dual digital / bargraph backlit display
LIMIT settings for automatic measurement evaluation

Saturn Geo Plus Three and Four Pole Earth Ground Tester (LEM)

The Saturn GEO Plus Earth Ground Tester not only enables the measurement of ground resistance using the classic fall of potential test but also using the ‘selective’ and ‘stakeless’ methods. The ‘selective’ test does not require the electrode under test to be disconnected before measurement, unlike other methods. The ‘stakeless’ method is quick and simple and replaces stakes with current transformers (probes) that are clamped around the ground conductor under test. Both techniques make it faster and safer to test.


Earth ground resistance and resistivity should be measured when:

• Installing new ground systems and
  electrical equipment
• Periodically testing ground and
  lightning protection rods
• Prior to design of ground protection systems
• Conventional three and four pole earth
  ground testing

Saturn Geo X Advanced Three and Four Pole Earth Ground Tester (LEM)

The Saturn Geo X Earth Ground Tester is ideal for measurement of ground resistance using the classic fall of potential test, as well as the ‘selective’ and ‘stakeless’ test. The ‘selective’ method does not require the electrode under test to be disconnected before measurement, unlike other methods. The ‘stakeless’ method is quick and simple and replaces stakes with current transformers (probes) that are clamped around the ground conductor under test. Both techniques make it faster and safer to test.


Earth ground resistance and resistivity should be measured when:

• Installing new ground system and
  electrical equipment
• Periodically testing ground and
  lightning protection rods
• Prior to design of ground protection
  systems

 

 

        Fluke 1620 Series GEO Earth Ground Testers

 

 

 

 

 

 

               Geo 30 Earth Ground Clamp (LEM)

 

 

 

 

           Handy Geo Earth Ground Tester (LEM)

 

 

 

 

       Saturn Geo Plus Three and Four Pole Earth Ground Tester (LEM)

 

 

 

 

 

 

 

 

 

 

 

 

     Earth ground resistance and resistivity should be measured when: